Cannon fenske viscometer pdf download

Tube viscometer cannonfenske size 100 from, your source for laboratory equipment and scientific supplies. Calculation of viscometer constants for cannonfenske routine and cannonfenske opaque viscometer filling is normally done at ambient temperature and the kinematic. Stokes law can be used to calculate the viscosity of the fluid. Cannonfenske routine viscometers, calibrated, technical. Low shear viscosities were obtained using a cannon fenske viscometer and a ta ar2000 stress rheometer with double concentric cylinder geometry. The cannonfenske routine viscometer measures kinematic viscosity of transparent newtonian liquids according to astm d445 and iso 3104.

Instructions for the use of the cannonfenske routine. Pdf viscosity has a huge impact for crude oils in quality and pricing. Oct 24, 2012 recommended viscosity ranges for cannon fenske routine viscometers approx. Used to measure kinematic viscosity of liquid cutback asphalts and road oils at 60c 140f in range of 30 to 6000 centistokes according to astm d 2170.

Gebrauchsanleitung cannonfenske routineviskosimeter. This report categorizes the market based on manufacturers, regions, type and application. Since the driving force is gravity and cannot be varied, the standardized. Cannonfenske routine viscometers supplied with cannon instrument companys isoiec 17025 report of calibration for measuring kinematic viscosity of transparent newtonian liquids, particularly petroleum products or lubricants, according to astm d 445 and iso 3104. Cannon fenske routine viscometers cannon fenske routine viscometers for transparent liquids. Determination of saybolt, kinematic, and shear viscosity for. Every viscometer made by fungilab has ben tested to ensure it follows the most strict rules in science. Cannonfenske petroleum viscometers glass viscometers. To support you, coleparmer is open for business and shipping product daily.

The cannonfenske routine viscometer see also astm d 445, d 446 and iso 3105 1. Calculation of viscometer constants for cannonfenske. A standard ball is allowed to fall down this tube over a calibrated distance of 100 mm. Astm d445, iso 3014, ip 71 part 1, bs 188 glass capillary size. A bohlin viscometer was utilized to determine the shear viscosity of vanilla yogurt, ketchup, glycerin, and shampoo. Clean the viscometer using suitable solvents, and by passing clean, dry, filtered air through the instrument to remove the final traces of solvents. Using a thermal bath, the viscosity at different temperatures can be measured. The viscometer should be cleaned with a suitable solvent and dried in a stream of clean, filtered or n 2. Cannon fenske routine viscometers comply with standards isodis 3105, astm d 2515, bs 188 with respect to technical measuring speci.

Cannonfenske viscometers for manual measurements vwr. Cannonfenske routine viscometers cannonfenske routine viscometers for transparent liquids. A fungilab viscometer is durable and thrustwhorthy. Cannonfenske routine viscometers comply with standards isodis 3105, astm d 2515, bs 188 with respect to technical measuring speci. Supplied with iso 17025 certificate of calibration. Kinematic viscosity was determined for diesel, biodiesel, and jet fuel using a cannon fenske capillary viscometer. Aa51711 viscometer, capillary type, cannonfenske reverse flow. Cannon 9721b62 viscometer, universal size 150 from coleparmer. All cannon glass capillary viscometers are traceable to a nist. We provide a broad range of viscosity standards and flash point reference materials to customers across various industries.

Viscometers, monitor and control, safety, consumables. The cannonfenske viscometer are suitable for all newtonian liquids with a viscosity of 0. Calibrated viscometers are supplied with a certificate of calibration and instruction sheet. Supplied complete with iso 17025 certificate of calibration. Permit measurements of liquids whose meniscus cannot be seen at the timing marks when using cannonfenske routine type viscometer. Utube viscometers modified ostwald viscometers psl. Sigmaaldrich offers a number of cannonfenske routine viscometer for transparent liquids products. The cannon fenske routine viscometer page 4 is a rugged and inexpensive viscometer that works well if the liquid to be measured is transparent or translucent. Clean the viscometer using suitable solvents, and dry by passing clean, dry, filtered air through the instrument to remove the final traces of solvents.

Msds download location for viscosity standards from psl rheotek. Total length 250mm 1840 cannon fenske routine viscometer for capillary diameter 0. Calculation of viscometer constants for cannon fenske routine and cannon fenske opaque viscometer filling is normally done at ambient temperature and the kinematic. The cannonfenske opaque reverseflow viscometer see also astm d 445. Our team takes all care in making every viscometer. Information and documents presented here are works of the u. In general, if the meniscus the curvature at the top of the liquid column can be readily observed through a column of liquid 3mm in diameter. Cannonfenske type viscometer tubes for measuring kinematic viscosity of petroleum products by astm d 445. Determination of viscosity of organic solvents theory. Psl rheotek utube viscometers are suitable for measuring transparent liquids. Rs 232 unidirectional interface, download to a computer.

However, this viscometer is not suitable for the manual or automatic measurement of. A continuous sensing capability for rapid viscosity measurement makes this economical dv1 digital viscometer a standout. Aa51711 viscometer, capillary type, cannon fenske reverse flow. Viscosity measurement using a brookfield viscometer request pdf. Buy cannon 9721b62 viscometer, universal size 150 and more from our comprehensive selection of cannonfenske routine viscometers covid19 update. Periodically, traces of n organic deposits should be removed with chromic acid or non. Cannonfenske routine viscometer, calibrated for manual.

During automatic measurement after being turned back into. Cannon fenske viscometers for manual measurements viscometers capillary viscometers suitable for transparent liquids, foaming liquids and liquid mixture with highly volatile components. View homework help canonfenske viscometer calibration. The sample should rest at least some 15 minutes in the measuring tube at the. Worldwide viscometers market manufactures and key statistics analysis 2017 the global viscometers market research report 2017 provides a detailed viscometers industry overview along with the analysis of industrys gross margin, cost structure, consumption value and sale price. The tube with capillary 1 is submerged in the liquid to be measured while suction using a hose is applied to the venting tube 2 until the liquid reaches the lower timing mark m2. Determination of saybolt, kinematic, and shear viscosity. Make sure this fits by entering your model number easy to operate, in line with iso3105. Viscometers have the serial number and size printed on the outside of the box and on the viscometer. Type bsu nominal overall length 300 mm, approximate sample volume 40 ml.

Description cannon fenske routine viscometer, model cfru100, uncalibrated, size 100. The key companies of the market, manufacturers, distributors along with the latest. We offer a variety of glass capillary viscometers because no single viscometer is ideally suited to every application. Viscosity measurement with ubbelohde, cannon fenske, and microostwald capillary viscometers. Our standards calibrate and verify the performance of glass capillary viscometers, automated kinematic viscometers, rotational viscometers. Astm d446, iso 3105, ip 71 part 2, bs188 astm ubbelohde test methods. Cannonfenske opaque viscometer, model cfou100, uncalibrated, size 100 list pricequantity total. It is applicable to materials having a viscosity range of 5000cst. Low shear viscosities were obtained using a cannonfenske viscometer and a ta ar2000 stress rheometer with double concentric cylinder geometry. The cannon fenske viscometer are suitable for all newtonian liquids with a viscosity of 0.

Total length 250mm 1840 cannon fenskeroutine viscometer for capillary diameter 0. Recommended viscosity ranges for cannon fenske routine viscometers viscosity range cst size approx. Viscosity measurement using cannonfenske viscometers. In the honour of hagenpoiseuille the unit of viscosity is called the poise p. Cannonfenske routine viscometer according to iso 3105 and astm d446 filling volume. However, this viscometer is not suitable for the manual or automatic measurement of opaque liquids. Also used to study shearing stress and shearing rate. It allows measurement of viscosity of newtonian fluids, using a capilary tube. Tube viscometer cannon fenske size 100 from, your source for laboratory equipment and scientific supplies.

Cannon 9721b65 viscometer, universal size 200 from cole. Cannon 9721b62 viscometer, universal size 150 from cole. If you are using cannon fenske routine viscometers as described in astm d 789, calibration must be done at 25c using 10 ml of a standard pipetted into the viscometer. Cannonfenske routine viscometer for transparent liquids. Viscosity measurement using a brookfield viscometer. Recommended viscosity ranges for cannonfenske routine viscometers viscosity range cst size approx. The cannonfenske opaque reverseflow viscometer and 2 pycnometer advertisement. For measuring kinematic viscosity of transparent newtonian liquids, particularly petroleum products or lubricants, according to astm d 445 and iso 3104. Intermediate shear rate rheology was evaluated with. The cannonfenske routine viscometer page 4 is a rugged and inexpensive viscometer that works well if the liquid to be measured is transparent or translucent. Astm ubbelonhde is a suitable for measuring transparent samples.

The viscometer should be cleaned with a suitable solvent and dried in a stream of clean, filtered or n2. Periodically, traces of organic deposits should be removed with chromic acid or nonchromium cleaning solution. Measures viscosity and temperature simultaneously with an optional temperature probe with a choice of 18 different speeds. These viscometerstubes are suitable for measuring transparent liquids. Cannon fenskeroutine the cannon fenske routine viscometer page 4 is a rugged and inexpensive viscometer that works well if the liquid to be measured is transparent or translucent.

Cannonfenske viscometers for manual measurements especially in routine analyses. View homework help canon fenske viscometer calibration. Utube viscometers modified ostwald viscometers psl rheotek. The direct or reverse flow styles have respectively positioned reservoirs to calculate the time it takes a specific fluid quantity to flow through the capillary. With its timed measurement function, data can easily be sent to a pc or printer. For use in the petroleum and chemical industriescalibrated with clear markings, the capillary viscometers support visual viscosity measurements of liquids. Cannon fenske routine suspended level, size 100, range 3 15. Mar 08, 2010 video about cannon fenske viscosimeter. Buy utube viscometerstubes, type of modified ostwald viscometers from pslrheotek.

Pdf design and fabrication of rotating cylinder viscometer. Cannonfenske series viscometers email this page print page not yet rated additional views. If you are measuring liquids whose meniscus cannot be seen at the timing marks, use the. These viscometers are preferably used for automatic measurements when an avs 24, avs 26 or avs 270 automatic viscometer cleaner is used simultaneously. According to specification sheets for cannon fenske.

Apr 27, 2015 falling sphere viscometer the falling ball viscometer is based on stokes law. Since the driving force is gravity and cannot be varied, the. Ostwald viscometer is a commonly used viscometer, which consists of a ushaped glass tube held vertically. Cannon fenske capillary viscometer rajesh scientific. Kinematic viscosity was determined for diesel, biodiesel, and jet fuel using a cannonfenske capillary viscometer. Pdf thermodynamic and time dependent of viscous flow of.

The ubbelohde viscometer page 5 and other suspended level viscometers are also used to measure transparent liquids. For a cannon fenske routine viscometer, the following equation permits calculation of the. Cannon cannonfenske routine calibrated viscometers, size. For more accurate measurements it is held in a controlled temperature bath. Market share, sales and revenue analysis by 2022 this report focuses on the blood viscometer in global market, especially in north america, europe and asiapacific, south america, middle east and africa. Since 1938 cannon instrument company has been a leader in viscosity measurement. Viscometer in oil and lubricant applications viscometry of oils and emulsions in all industrial application fields, in which oils, gels and emulsions are pumped, stirred and filtered as well as are treated physically and chemically in product circulations, the flowability of these substances plays a very important plant engineering role.

Falling sphere viscometer the falling ball viscometer is based on stokes law. Use of high quality instruments ensures test reliability and accuracy. Astm d2515, iso 31043105 and une 4003 cannonfenske opaque viscometers reverse flow type are used for dark newtonian liquids. Buy cannon 9721b65 viscometer, universal size 200 and more from our comprehensive selection of cannonfenske routine viscometers covid19 update. Cannonfenske routine viscosity tubes, uncalibrated. This type of viscometer consists of a circular cylinder filled by the liquid under investigation. Complete with ukas certificate of calibration iso 17025. Government and are not subject to protection in the u. Cannon instrument company has been making glass capillary viscometers since 1938.